Global Supplier of HVAC refrigeration equipment and accessories and tools

ZR125KCE-TFD-522 10HP Emerson Copeland Scroll Compressor

  • Copeland scroll axial and radial compliance for superior reliability and efficiency

  • Wide scroll line-up for R407C and R134a

  • Low TEWI (Total equivalent warming impact)

  • Low sound and vibration level

  • Low oil circulation rate

  • Copeland qualified tandem and trio configurations for superior seasonal efficiency (ESEER)



Copeland ZR125KC Compressor

The Copeland ZR125KC series scroll compressors are high-performance air conditioning and refrigeration compressors produced by Emerson Climate Technologies. This series of copeland compressors is widely used in air conditioning, industrial cooling, and precision air conditioning fields, and is widely recognized in the market for its high efficiency, reliability, and low noise.


ZR125KC Copeland Compliant Scroll Compressor

Product Name
Copeland
Model
ZR125KCE-TFD-522
Package
Wooden Case
Application
HVAC
Cooling Capacity
103000BTU
MOQ
1 Piece
COP
3.40W/W
Net Weight
61.2KG
E.E.R
11.6Btu/W
Voltage
380-420V/3/50Hz
Oil Change[Dm3]
3.25
RLA
16.0 A

Product Features

  • High Efficiency: Utilizing the Copeland Scroll™ axial and radial flex technology, the compressors ensure high efficiency operation under various operating conditions.

  • Wide Capacity Range: Single compressors have a capacity range from 5kW (ZR18) to 90kW (ZR380), with dual machine paralleling and triple machine paralleling options available.

  • Low Oil Circulation Rate: Reduces the amount of oil used, lowering operating costs.

  • Superior Liquid Floodback Capability: Maintains stable operation under liquid floodback conditions, extending compressor life.

  • Low Noise and Vibration Levels: Provides a quieter operating environment, reducing impact on the surrounding environment.

  • Low LCCP (Life Cycle Climate Performance): Minimizes environmental impact throughout the product's lifecycle.

Application Considerations

  • Operating Envelope: The operating envelopes for the ZR*KC compressors with R-22, R-407C, R-134a, and R-410A are illustrated in Figure 2 of the technical bulletin. The steady-state operating condition of the compressor must remain inside the prescribed operating envelope.

  • Internal Pressure Relief (IPR) Valve: The IPR valve is designed to relieve excessive pressure within the compressor to protect it from damage.

  • Continuous Floodback Test: It is necessary to operate the system in a test room at conditions where steady-state floodback may occur to test for excessive continuous liquid refrigerant floodback.


After-Sales Service from Bobiller

  • Technical Support: Comprehensive technical support is provided, including installation guidance, troubleshooting, and maintenance recommendations.

  • Warranty Service: Enjoy the standard warranty service from Emerson Climate Technologies to ensure the long-term stable operation of the product.

  • Spare Parts Supply: A wide range of spare parts are available to ensure quick repairs when needed.


Certification Standards

  • EN 142761: Complies with the European standard EN 142761 to ensure product quality and safety.

  • EN 60335-2-34: Complies with the European standard EN 60335-2-34 to ensure electrical safety.


Installation Guidelines

  • Pressure Testing: Use dry nitrogen for pressure testing, and avoid using other industrial gases.

  • System Vacuuming: Before installation, use a vacuum pump to evacuate the system to an absolute pressure of 3 mbar to reduce residual moisture.

  • Electrical Connections: Ensure proper cable connections and use appropriate cable sealing to achieve the specified protection level.


Frequently Asked Questions

  • Q1: How to choose the right refrigerant and lubricant?

    A1: Please choose the appropriate refrigerant and lubricant according to the compressor model and application requirements. Specific models and oil quantities can be found in the technical manual or by consulting technical support.

  • Q2: What preparations are needed before starting the compressor?

    A2: Before starting, ensure that the crankcase heater has been on for at least 12 hours to prevent oil dilution and bearing stress.

  • Q3: What is the maintenance cycle for the compressor?

    A3: It is recommended to perform routine maintenance every six months, including checking the oil level, cleaning the filter, and inspecting electrical connections.



ZR125KCE-TFD-522 10HP Emerson Copeland Srcoll Compressor

ZR125KCE-TFD-522 10HP Emerson Copeland Scroll Compressor
ZR125KC Copeland Compressor Specification

ZR125KCE-TFD-522 10HP Emerson Copeland Srcoll Compressor



Bobiller, The Best Mate!

Our company offers a complete line of heat pump units and refrigeration equipment systems, as well as refrigeration compressors, copper fittings, expansion valves, dual-measure gauges, and other accessories and tools, so you can get everything you need for the refrigeration industry in one place. And we can provide you with customized manufacturing services.

New High-Efficiency Compressor Series for HVAC & Refrigeration Applications

New High-Efficiency Compressor Series for HVAC & Refrigeration Applications

We are proud to launch our next-generation compressor portfolio, including rotary, scroll, and reciprocating models. These compressors deliver enhanced efficiency, reliable performance, and compliance with global environmental standards, meeting the growing demand for sustainable cooling solutions worldwide.

Apr. 08, 2026

The Core Value of Water Tanks in Hotel Heat Pump Systems

The Core Value of Water Tanks in Hotel Heat Pump Systems

R290 heat pumps are capable of effortlessly delivering hot water at temperatures reaching up to 75°C. This makes them ideally suited for retrofitting heating systems in older buildings, where they can serve as a direct replacement for existing gas boilers without the need to replace the entire heat distribution infrastructure.

Mar. 16, 2026

Local School Heating Retrofit Completed with 18kW Units

Local School Heating Retrofit Completed with 18kW Units

Many schools face challenges with heating their buildings effectively. Traditional systems can lead to high energy bills and discomfort. However, air source heat pumps offer a modern approach. These systems use renewable energy from the air to provide heat. As concerns about climate change rise, more schools are considering efficient heating solutions. The retrofit project at the local school

Oct. 06, 2025

Regional Health Center Achieves Carbon Neutral Goals Using Heat Pump System

Regional Health Center Achieves Carbon Neutral Goals Using Heat Pump System

The air source heat pump supplier has become essential in the quest for energy-efficient solutions. Many healthcare facilities seek ways to reduce their carbon footprint while maintaining optimal comfort for patients and staff. Traditional heating and cooling methods can be both costly and environmentally harmful. Healthcare providers are increasingly turning towards innovative systems like air

Oct. 03, 2025

300-Bed Hospital in Southeast Asia Replaces Water Boiler with Bobiller System

300-Bed Hospital in Southeast Asia Replaces Water Boiler with Bobiller System

300-Bed Hospital in Southeast Asia Replaces Water Boiler with Bobiller System

Oct. 02, 2025

Ski Resort Improves Guest Comfort with 50kW Low-Noise Heat Pump System

Ski Resort Improves Guest Comfort with 50kW Low-Noise Heat Pump System

The ski industry constantly seeks ways to enhance guest experience and comfort, particularly with temperature control in chilly weather. A 50kW low-noise heat pump system can serve this purpose exceptionally well. Unlike traditional heating systems, a heat pump provides an energy-efficient solution while maintaining a quiet environment—a major factor for guest satisfaction. This article

Oct. 01, 2025

Remote Medical Clinic Installs 5 Modular Heat Pumps for Patient Room Comfort

Remote Medical Clinic Installs 5 Modular Heat Pumps for Patient Room Comfort

Air source heat pump suppliers provide essential solutions for maintaining comfort in various environments. In a remote medical clinic, the comfort of patients is a top priority. However, many clinics struggle with maintaining stable indoor temperatures. This challenge can negatively impact patient recovery and overall satisfaction. To solve this problem, the clinic decided to install five

Sep. 30, 2025

Rural Campus Upgrades Dormitory Heating with 12 Centralized Heat Pump Units

Rural Campus Upgrades Dormitory Heating with 12 Centralized Heat Pump Units

The upgrade of heating systems in dormitories is crucial for energy efficiency and comfort. A rural campus recently faced a common problem: outdated heating methods that were neither efficient nor cost-effective. The solution? Installing 12 centralized air source heat pump units. These heat pumps provide a sustainable heating solution, reducing energy consumption significantly. Moreover, they

Sep. 29, 2025

CONTACT US

Tel.: +86 15102038129

E-mail: MarkYang@bobiller.com

WhatsApp: +86 15102038129

Add.: No.123 Yingbin Avenue, Wuding High City, Huadu District, Guangzhou

GET IN TOUCH

Copyright © Bobiller (Guangzhou) Refrigeration Equipment Co., Ltd. All Rights Reserved | Sitemap | Powered by Reanod